A cold garage can fall within a launch monitor’s operating range while remaining unsuitable for its projector, charging routine or long-term storage. Plan the building environment around every component and address condensation before installing expensive equipment.
Research-based buying guide, checked 13 September 2026. We have not carried out hands-on testing. Product details come from the linked official sources; the comparison and trial suggestions are our editorial advice.

Table of Contents
One simulator has several environmental limits
The Garmin Approach R50 manual specifies operation from −10°C to 55°C, but charging from 3°C to 47°C. For storage over several months it recommends a cool, dry place around normal household temperature and at least 50% battery charge. An operating limit therefore does not approve leaving the unit charging through a freezing night.
For a different component, the BenQ LH835ST projector manual specifies operation at 0–40°C at sea level and 10–90% relative humidity without condensation. Its wider storage temperature range does not permit use at those storage extremes. These examples apply to the exact named models; check the PC, display, charger and any replacement projector separately.
| Component or task | Verified example or check | Practical implication |
|---|---|---|
| R50 operation | −10 to 55°C | Do not apply this range to the rest of the bay |
| R50 charging | 3 to 47°C | A cold device may be outside the permitted charging range |
| LH835ST operation | 0–40°C; non-condensing environment | Being above freezing alone does not meet every condition |
| Storage between sessions | Exact manual for every component | An operating specification is not a storage plan |
| Building condition | Survey moisture, ventilation and insulation | A heater purchase cannot diagnose the source of damp |
Find the moisture source before adding equipment
Energy Saving Trust’s damp guidance distinguishes condensation on cold surfaces from other moisture problems, including rain entering through defects. It advises resolving underlying causes and maintaining suitable ventilation when improving insulation or draught proofing. That is a useful starting principle, not a diagnosis of your garage.
Record where moisture appears and when: after rain, after the car comes in wet, after a practice session, or when a cold room is warmed. Photograph roof or wall staining and ask a qualified building professional to assess persistent damp. Include the proposed screen and wall coverings in that assessment, because concealing a damp patch does not remove its cause.
Allow for changing conditions, not just a warm reading
Take temperature and humidity readings over representative cold days, including before and after use. A simple logger can reveal how variable the space is, but an air reading does not prove that the inside of a cold device is dry. Ask each manufacturer for its instructions on moving equipment between cold and warmer environments and any required acclimatisation.
Do not invent a universal waiting period or use direct heat to rush equipment into service. If condensation is visible or the manufacturer’s conditions are not met, stop and establish the proper procedure before powering or charging it. A splash-resistance label is not evidence that an electronic device tolerates internal condensation.
Commission a room plan with a defined scope
Ask the surveyor or installer to separate weatherproofing repairs, insulation, ventilation and any heating or moisture-control proposals. Request the reason for each measure, its operating conditions, maintenance and running-cost assumptions. A dehumidifier should be selected for the actual room and temperature; we have not verified a particular model as a solution for your garage.
Have a qualified electrician assess the supply and planned equipment locations. Include normal storage, cable routes and ventilation clearances in the drawing. Avoid committing to a screen enclosure before the room works are defined: new linings, floor build-up or insulation can change the usable geometry. Our simulator projector guide covers the separate image and throw-distance decision.
Decide what stays in the garage
A portable monitor and computer may be easier to store in a suitable indoor location between sessions, following their manuals. A permanently mounted projector or overhead monitor makes the garage’s year-round conditions more consequential. Agree a storage and startup routine before choosing between those approaches, including who checks it when the room is unused for weeks.
Obtain a written quote for the assessed building work and simulator installation rather than a national “garage conversion” average. This article supplies planning checks, not a site inspection or installed-cost estimate. Use our simulator component guide to list the equipment, then attach each manufacturer’s environmental requirements to the room brief. Buy monitoring accessories to gather information, not as proof that the space has been made suitable.
These affiliate links open Amazon UK search results for the named equipment or accessories.
- Search Amazon UK for digital temperature humidity data logger
- Search Amazon UK for golf simulator storage case
Check the exact model, generation and seller. Results can include alternatives; a search link does not confirm availability. Use the official supplier links for specialist products and services.
Sources and how to use this guide
Read the linked manufacturer or service information alongside the exact item offered to you. Specifications describe the named model; an individual build, package or previously owned item may differ. Confirm the complete order before paying. We have not verified a universal performance winner or promised stock availability.